Designed specifically to address the needs of rack-mounted systems in data center environments, the SprayCool™ M-Series offers unique business and technical benefits.

SprayCool’s unique closed-loop liquid cooling system offers significant cost and energy savings in managing heat in densely populated data centers.  It allows power consumption to be lowered by around 40% over conventional cooling systems.  In many cases processing capacity can be doubled without the installation of additional HVAC systems.

How it works
M-series is a rack level solution that consists of a SprayCool enabled rack ready to support SprayCool enabled servers from major manufacturers. Each server is fitted with a SprayCool module per processor which attaches to the SprayCool system at the back of the rack. Heat from the CPU’s is removed from the servers, transported to the bottom of the rack and then rejected from the room entirely through heat exchange with facility water loop. The SprayCool M-Series can support up to 10,800 Watts per rack without impacting air cooling requirements for existing legacy equipment in the datacenter.

Business Benefits
SprayCool enables data centers to be built in a substantially more efficient manner – reducing both upfront costs and operating costs. Organizations can save millions of dollars in real estate and energy. New data centers can be built smaller and provide operational efficiency gains resulting in reduced construction times, and most importantly reduced capital costs.

  • Fully populate server racks and increase power density without a significant increase in heat.
  • Reduce the amount of floor space required for cooling equipment.
  • Decrease power costs.
  • Revolutionize how data centers are designed, built, and operated.
  • Increase the computing power in data centers.
  • Decrease server failure due to heat damage.

Technical Benefits

  • Requires less than 200w to run cooling system
  • Fully Scaleable--Holds up to 36 1u servers
  • Adaptable for 2u Servers
  • Rejects heat into existing facility water loop
  • Redundant, hot-swappable pumps and dual power supplies are standard

Servers Supported

HP
Proliant DL
Proliant ML
DL140G2 DL560* ML150*
DL145G2 DL580* ML330*
HPDL360G4p DL585* ML350*
DL380* DL740* ML370*
DL385* DL760* ML570*

Dell
PowerEdge
PE 750* PE 2850*
SC 1425 PE 2950
PE 1850 PE 6850*
PE 1950 PE 7250*

IBM
X-Series
x306* x343*
x326 x346*
x336 x365*
x366* x3550

* Future Support. Contact commercial sales for availability.

Performance Options

 

Target Uptime
Maintenance
Service Response

Performance

99.5%

As Needed

24 hours

High Availability

99.99%

Annual

12 hours

Mission Critical

99.999%

Predictive

4 hours